• US
  • Solutions
    • Fire protection curtains

      Fire protection curtains

      Fire protection curtains are seal openings in walls and ceilings in case of fire. The constructional set-up (rolling- or folding technology) and the use of different fabrics offer a wide application spectrum as well as different protection targets or classifications and time classes. Casings and side guides of those flexible applicable systems are integrated almost invisibly in the building and provide much scope for design of sophisticated architecture for opened designs.

    • Conveyor system closures

      Conveyor system closures

      Manifold production - and logisitc processes require different construction types of conveying systems. If the haulage drifts are passing through fire-retarding resp. fire-resisting walls or ceilings, the necessary openings must be provided with fire protection closures to avoid the expansion of the fire by conveyor technique or by conveyed material. In case of fire the conveyor system closures have to seal those openings immediately and automatically. Thereby a classified fire resistance as well as the smoothly clearing of the closing area must be respected in case of release.

    • Smoke curtains

      Smoke curtains

      A smoke curtain is part of unit keeping areas free from smoke and may include building parts like natural smoke and heat venting systems and automatic smoke and heat venting systems. Smoke curtains restrict the movement of fire gases inside a building in case of fire.

    • Smoke protection closures

      Smoke protection closures

      In closed condition smoke protection closures restrict the passage of smoke in the phase of fire formation so as to enable the rescue of people, animals or materials assets in case of a fire in the room positioned behind it without the need of breathing protection.

    • Tube sealings

      Tube sealings

      The solution to problems with fire protection dampers for ventilation and air conditioning systems in conveying processes. Stöbich offers fire protection for pneumatic conveying lines where the closing elements are not exposed to the flow. Thus, damage or contamination of the closure element is avoided by abrasive conveyed goods.

    • Controls

      Controls

      Control systems are necessary for all automatic fire protection systems! They are safety-relevant, because without their function or in the event of a malfunction, the entire investment of a fire protection partition would be useless. Controllers coordinate both fire detection and the interaction with other controls, like superordinate building control or the retraction of the closing area at conveyor closing area.

    • Médiathèque Charles Nègre | Grasse, France

      Médiathèque Charles Nègre | Grasse, France

      The Médiathèque Charles Nègre in Grasse, France, is an impressive example of contemporary architecture that reflects the cultural and historical importance of the region. The information center with space for education, culture and encounters was opened in 2011 and designed by the renowned French architecture firm Marc Barani. The building combines modern aesthetics with the traditional architecture of Provence, creating a harmonious link between old and new, for example by combining modern materials such as glass and steel with local natural stone. The generous window fronts create an atmosphere flooded with light. Ecological sustainability is achieved through natural ventilation and the resulting reduction in energy consumption; green spaces are also integrated on various levels. Our <a href="/us/solutions/fire-protection-curtains/stoebich-fire-smoke-curtain-hc"><b>➥ horizontal Fire and smoke curtain hc</b></a> fire protection curtains fit perfectly into this marvel of contemporary architecture. They securely close the ceiling openings in the event of a fire, but otherwise remain invisible and let in plenty of light and air. Copyright attribution: © Ivry Serres

  • Theme worlds
  • News
  • Contact
  • STÖBICH Brandschutz: Austria Contact

Stoebich Smoke Curtain S

(Kopie 2)

  • Smokeshield-S

Product description

Rectangular and polygon-shaped basic surface of the smoke protection curtain. Edge dimensions up to 629,92" and unrolled lengths of up to 236.22".

- For high time class and temperature loads D120 (1,112 °F)
- Without residual openings - neither in the upper area nor in the corners
- No support necessary, despite this absolutely tight even under pressure loads
- Low installation height of the casing of approx. 4,92" at an AL < 118.11"
- As standard with the 'Gravigen' drive system, i.e. closes without any external energy
- Fire-resistant cables are not necessary
- Redundant drive systems as a fall guard
- Suitable (approved) also as a floor-closing smoke protection curtain

|
Construction typeTextile smoke curtain
FabricFire & Smoke Fabric E
ProofZ - 56.429 - 916 (fabric) | IBS 08062415 | UB 3.3/ 10-018-1
Closing directionFrom top to bottom
Feasible sizeUp to 164 ft. circumference or 19.7 ft. drop length
Closing cyclesC self-closing
Guide typeSide guides | without guide rails
ClassificationClassification according to DIN EN 12101-1
TriggeringApproved hold-open system | To be provided on site
Stoebich Smoke Curtain S

Legend system components:
1 = Smoke detector
2 = Casing
3 = Side guids
4 = Tubular motor
5 = Fabric
6 = Closing element
7 = Coil
8 = Control module
9 = Control with operating unit
10 = Manual release
SL = System length

Constructive system design (System drawing)

Fabric System widthDrop length (AL)t (mm)h (mm)
Ecotex 1100 A2< 50 m< 3 m490125
Ecotex 1100 A2< 50 m> 3 m - ≤ 6 m490225
Heliotex EW 90< 50 m≤ 2,2 m490125
Heliotex EW 90< 50 m> 2,2 m - ≤ 4,5 m490225
Heliotex EW 90< 50 m> 4,5 m - ≤ 6 m490450

Bottom Bar


Closing strips Fibershield-S
Standard
Closing strips Fibershield-S
Sonder
With light spots or light strip

Housing


Fibershield-S Casing
Housing (open)
h = from table
t = 490 mm

d = 290 mm
Fibershield-S Casing
Locking equipment (optional)
h = 125 mm
t = 490 mm

d = 290 mm
S = Infrared fuse